Aegis® PIR-H85NP is a medium viscosity, nylon 6 extrusion grade homopolymer for cast or blown BOPA film.
Properties
- Physical Form
- Thermal Properties
Value Units Test Method / Conditions Melting Point 220 (428) °C (°F) D-3418 - Typical Properties
Value Units Test Method / Conditions 96% SAV 3.19 - - Density 1.13 g/cm³ ASTM D-1505 Melt Flow Rate (at 235°C/1.0 kg or 455°F/1.0 kg) 3.5 g/10 min D-1238 Viscosity (FAV) 85 - D-789 - Gas Barrier Properties
Value Units Test Method / Conditions Carbon Dioxide Permeability (at 23°C (73°F), 0% RH) 72.8 (4.697) cc/m²/day (cc/100 in2/day) - Nitrogen Permeability (at 73°F (23°C), 0% RH) 14.0 (0.903) cc/m²/day (cc/100 in2/day) - Oxygen Permeability (at 73°F (23°C), 0% RH) 40.3 (2.600) cc/m²/day (cc/100 in2/day) - - Moisture Properties
Value Units Test Method / Conditions Equilibrium Moisture (at 50% RH) 2.7 % - Extractable Content max. 0.6 % - Moisture Content max. 0.08 % - Saturation Moisture Content 9.5 % - Water Absorption in 24 hrs 1.6 % - - Note
Aegis® PIR-H85NP conforms to FDA requirements of 21 CFR 177.1500 as well as EU Directive 2011/10/EC. Aegis® PIR-H85NP homopolymer possesses the combination of strength, toughness and thermoforming properties associated with nylon 6 as well as excellent heat, chemical and abrasion resistance.
Regulatory & Compliance
- Certifications & Compliance
Storage & Handling
- Material Handling
Aegis® PIR-H85NP is supplied in sealed containers and drying prior to processing is not required. However, higher moisture is the primary cause of processing issues. If drying becomes necessary, a dehumidifying or desiccant dryer operating at 80°C (176°F) is recommended. Drying time is dependent on moisture level. More information about safe handling procedures can be obtained by requesting the Safety Data Sheet.